BKLTV - ALKALINE BATTERY/CELL BA-31
- MSDS: BKLTV
- Manufacturer: BREN TRONICS INC
- Product Name: ALKALINE BATTERY/CELL BA-31
- National Stock Number: 6135-00-120-1019
Product Identification
Product ID:ALKALINE BATTERY/CELL BA-31
MSDS Date:03/01/1991
FSC:6135
NIIN:00-120-1019
MSDS Number: BKLTV
Responsible Party
COMMACK, NY 11725-3104
US
Emergency Phone: 516-499-5155
Cage: 51828
Contractor
Telephone: 631-499-5155
Cage: 51828
Ingredients
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 5-9%
OSHA PEL C, 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
MANGANESE DIOXIDE
CAS: 1313-13-9
RTECS: OP0350000
Fraction By Weight: 32-38%
OSHA PEL 5 MG/M3 CEILING
ACGIH TLV: 5 MG/M3 (AS MN DUST)
ZINC (SARA III)
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 11-16%
OSHA PEL 10 MG ZNO/M3
ACGIH TLV: 10 MG ZNO/M3; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
MERCURY (SARA III)
CAS: 7439-97-6
RTECS: OV4550000
Fraction By Weight: <1%
OSHA PEL S, C, 0.1 MG/M3
ACGIH TLV: S, 0.05 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THESE CHEMICALS ARE CONTAINED IN A
SEALED CAN. RISK OF EXPOSURE OCCURS ONLY IF THE BATTERY IS
MECHANICALLY OF ELECTRICALLY ABUSED. MOST LIKELY, RISK IS WHEN A
CELL LEAKS. KOH IS CAUSTIC AND SKIN CON TACT CAN CAUSE IRRITATION
OR BURNS. EYE CONTACT CAN CAUSE PERMANENT INJURY.
Effects of Overexposure:SKIN AND EYE CONTACT WITH KOH MAY CAUSE BURNS.
AT ELEVATED TEMPERATURES, HG VAPOR MAY BE PRESENT AND SHOULD NOT BE
INHALED.
Medical Cond Aggravated by Exposure:AN ACUTE EXPOSURE WILL NOT
GENERALLY AGGRAVATE ANY MEDICAL CONDITION.
First Aid
First Aid:IF LEAKAGE FROM CELL CONTACTS: SKIN-FLUSH WITH WATER AND WASH
WITH SOAP AND WATER; EYES-FLUSH WITH COPIOUS AMOUNTS OF WATER FOR
15 MINUTES THEN SEE PHYSICIAN AT ONCE.
Fire Fighting
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS WHEN A LARGE NUMBER OF CELLS ARE INVOLVED.
Unusual Fire/Explosion Hazard:CELLS MAY RUPTURE WHEN HEATED
EXCESSIVELY; MAY RELEASE TOXIC MERCURY AND CORROSIVE MATERIALS WHEN
INTEGRITY OF CELL CAN IS BROKEN.
Accidental Release
Spill Release Procedures:AVOID SKIN AND EYE CONTACT. DO NOT INHALE
VAPORS. COLLECT ALL RELEASED MATERIAL IN PLASTIC BAG FOR WASTE
DISPOSAL.
Handling
Handling and Storage Precautions:STORE IN DRY PLACE. DO NOT RECHARGE.
DO NOT SHORT CIRCUIT.
Other Precautions:USE BATTERY ONLY IN PROPER EQUIPMENT. OBSERVE
CORRECT POLARITY WHEN INSTALLING INTO EQUIPMENT. DO NOT ATTENPT TO
RECHARGE.
Exposure Controls
Respiratory Protection:AS IN ANY FIRE SITUATION, USE SELF-CONTAINED
BREATHING APPARATUS.
Protective Gloves:USE WHEN HANDLING LEAKING BATTERIES
Supplemental Safety and Health
Chemical Properties
HCC:N1
Appearance and Odor:RECTANGULAR WITH ROUNDED CORNERS
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:DO NOT HEAT, DISASSEMBLE, OR RECHARGE. DO
NOT SHORT CIRCUIT.
Hazardous Decomposition Products:WHEN HEATED, CELLS MAY EMIT HAZARDOUS
VAPORS OF HG OR CAUSTIC KOH.
Disposal
Waste Disposal Methods:IN SMALL QUANTITIES, BATTERIES MAY BE DISPOSED
OF WITH HOUSEHOLD TRASH. DO NOT INCINERATE. DISPOSE OF LARGE
QUANTITIES IN ACCORDANCE WITH LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.